Ladder (or scaffold if required)
Nails or Screw
Measuring tape
Drop cloth
Drill
Pencil
Marley MCS® Solvent Cement
Builders level
Hack saw (fine tooth PVC saw)
String line / Chalk line
Install expansion outlet as per spouting installation instructions.
Connect downpipe bend to expansion outlet using a screw to hold bend in place. To allow easy removal for cleaning debris do not solvent cement bend to outlet
Determine the offset length (A) using Figure 2 allowing for depth of socket and taking into consideration the downpipe bracket distance from the wall (B). Cut downpipe as per measurements.
Solvent cement all remaining elbows to downpipe on ground, before completing offset installation.
Use a level or plumb line to mark where the downpipe will sit against the wall. Ensure brackets are spaced no more than 1.2m apart and the first clip is a maximum of 200mm below the downpipe bend. Downpipe clips to be secured with two stainless steel screws.
Connect downpipe to access pit, surface drainage or stormwater outlet. N.B. Do not connect downpipe to waste water gully trap. Check project is complete and all joins are clean