SecuraOne® Flow Rate Test Vs. Competitors Flow Rate Test
We recently simulated a standard 3 bed/2 bath house fit out in the Marley warehouse to prove that SecuraOne® was comparable in flow rate to SecuraGold™ and any other competitor PB or PEX system.
The results are in and the data supports a REAL flow rate comparison showing that fixtures are the biggest limiter of flow rate. Plumbers can move to SecuraOne® knowing there is limited difference in flow rate compared to all other hot and cold systems.
The difference between our Flow Rate Test and our competitors
| SecuraOne® Flow Rate Comparison Test | Competitors Flow Rate Comparison Test | |
|---|---|---|
| 5m + of 20mm SG and S1 pipe replicating the main used in a house fit out | ||
| 16mm S1 and 15mm SG droppers to fixtures | ||
| Additional fittings to replicate the number used in a house fit out (also a flow limiter) | ||
| Fixtures like mixers and shower heads (with small IDMs) | ||
| Multiple fixtures running at the same time to show flow rate with all taps on | ||
| Data points captured as further proof of comparable flow rate |
Flow Rate Data Set #1
Flow rate analysis, filling to 20L bucket at system pressure (450kPA) and low pressure (300kPA).
| 450kPA | 300kPA | |||
|---|---|---|---|---|
| Fixture | S1 / SG | Pressure Loss | Pressure Loss | |
| Kitchen | S1 | 15 | 35 | |
| SG | 15 | 30 | ||
| Shower 1 | S1 | 50 | 60 | |
| SG | 45 | 50 | ||
| Shower 2 | S1 | 80 | 70 | |
| SG | 45 | 40 | ||
| Shower 3 | S1 | 100 | 80 | |
| SG | 60 | 60 | ||
| Hose Tap | S1 | 400 | 280 | |
| SG | 380 | 260 | ||
SecuraOne® Flow Rate Calculator
Calculates the normal pressure losses incurred during water reticulation through 12mm, 16mm, 20mm, 25mm and 32mm PB and PEX pipes.
* L/min relates to the NZBC G12/AS1 acceptable flow rates to sanitary fixtures.
** Allow 1m per fitting.
Pressure Loss Calculator Disclaimer:
Calculates the friction loss or pressure drop for water flowing through PB or PEX pipes and SecuraOne® brass fittings.
No warranty of any kind is expressed or implied and no liability will be accepted by Marley New Zealand Limited for any costs arising directly or indirectly as a result or consequences of the use of this calculator.
This calculator is provided to assist users to understand the normal pressure losses incurred during water reticulation through PB and PEX pipes. While the formulae and calculations have been verified independently as accurate and have been based on the best available information at the time of publication, no warranty of any kind is expressed or implied and no liability will be accepted by Marley New Zealand Limited for any costs arising directly or indirectly as a result or consequences of the use of this calculator.
Any queries or suggestions concerning this calculator and the information generated by it should be emailed to info@marley.co.nz